ELECTRIC HOT WATER BOILER
CLDR Electric Hot Water Boiler
A clean, compact electric hot-water boiler family covering 24–1,440 kW for heating and indirect process-water duties where a suitable electrical supply is available.

- Rated Power
- 24–1,440 kW
- Water Temperatures
- 85 / 60°C
- Listed Efficiency
- 98%
- Electrical Basis
- 380 V / 50 Hz
PRODUCT OVERVIEW
Staged Electric Heating with Eleven Listed Power Levels.
CLDR uses electric heating elements, circulation control and a digital controller in a compact packaged arrangement. It is suited to projects that prioritize local zero-combustion emissions, quiet operation and straightforward plant-room integration.
The selected model must be checked against the building or process heat balance, electrical transformer capacity, distribution system, circulation flow and destination electrical rules.
CLDR-24/36/48
24–48 kW compact range
CLDR-72/108/144
72–144 kW medium range
CLDR-216/360/504
216–504 kW industrial range
CLDR-720/1440
720–1,440 kW high-load range
WORKING PRINCIPLE
Electrical Energy Is Staged into the Circulating Water Loop.
Treated water circulates through the boiler and external load. The controller stages the electric heating groups according to outlet-water temperature and load demand.
Protection logic monitors water availability, temperature, circulation and electrical conditions. Final sensors, interlocks, pumps and redundancy follow the approved electrical and hydraulic design.
TECHNICAL DATA
Verified Listed Models and Operating Data.
The table keeps model identities and values separate. Final dimensions, interfaces, components and site performance follow the approved technical proposal and drawings.
| Model | Power | Rated Capacity | Outlet / Return | Efficiency | Weight | Dimensions (L×W×H) |
|---|---|---|---|---|---|---|
| CLDR-24KW-D | 24 kW | 2 ×10⁴ kcal/h | 85 / 60°C | 98% | 0.18 t | 800×700×1000 mm |
| CLDR-36KW-D | 36 kW | 3 ×10⁴ kcal/h | 85 / 60°C | 98% | 0.20 t | 800×700×1000 mm |
| CLDR-48KW-D | 48 kW | 4 ×10⁴ kcal/h | 85 / 60°C | 98% | 0.22 t | 800×700×1400 mm |
| CLDR-72KW-D | 72 kW | 6 ×10⁴ kcal/h | 85 / 60°C | 98% | 0.25 t | 800×700×1400 mm |
| CLDR-108KW-D | 108 kW | 9 ×10⁴ kcal/h | 85 / 60°C | 98% | 0.32 t | 1300×1100×1600 mm |
| CLDR-144KW-D | 144 kW | 12 ×10⁴ kcal/h | 85 / 60°C | 98% | 0.36 t | 1300×1100×1600 mm |
| CLDR-216KW-D | 216 kW | 18 ×10⁴ kcal/h | 85 / 60°C | 98% | 0.56 t | 1500×1100×1700 mm |
| CLDR-360KW-D | 360 kW | 30 ×10⁴ kcal/h | 85 / 60°C | 98% | 0.80 t | 1800×1600×1800 mm |
| CLDR-504KW-D | 504 kW | 42 ×10⁴ kcal/h | 85 / 60°C | 98% | 1.10 t | 1800×1600×2000 mm |
| CLDR-720KW-D | 720 kW | 60 ×10⁴ kcal/h | 85 / 60°C | 98% | 1.60 t | 2200×1600×2000 mm |
| CLDR-1440KW-D | 1,440 kW | 120 ×10⁴ kcal/h | 85 / 60°C | 98% | 3.50 t | 4000×1600×2000 mm |
Selection: Confirm the real heat or steam load, operating profile, utility conditions and destination requirements before selecting a model.
Performance: Actual consumption and efficiency depend on delivered energy quality, load, temperatures, tuning, system losses, maintenance and the agreed test boundary.
PROJECT ENGINEERING
Confirm Electrical Capacity and Hydraulic Conditions Before Model Selection.
A reliable proposal starts with measured or calculated project data rather than only a nominal model name.
Send project data- 01Heat Load
Provide normal and peak duty plus operating hours.
- 02Electrical Supply
Confirm voltage, frequency, transformer rating and available current.
- 03Water Circuit
Provide supply/return temperatures, flow and system pressure.
- 04Water Quality
Send analysis and planned treatment route.
- 05Controls
Define duty/standby pumps, remote signals and building-control interface.
- 06Destination Rules
Confirm electrical, pressure, inspection and installation requirements.
SYSTEM ROUTE
Coordinate the Equipment, Utilities, Controls and User Load.
The primary equipment is one part of a complete system. Final pipe sizes, pump duties, valves, instruments and site interfaces follow the approved design.

PROJECT SCOPE
Define Every Included Item and Site Responsibility.
The formal proposal identifies the exact model, controls, auxiliaries, instruments, documentation and customer interfaces. Items are included only when stated in the agreed scope.
Civil works, site piping, electrical cabling, utility connections, installation, destination approvals, registration, inspection and testing are included only when explicitly stated.
APPLICATIONS
Match the Equipment to the Real Process and Operating Pattern.
Final suitability depends on load, temperatures or pressure, operating hours, utilities, water quality, emissions and destination requirements.
Commercial Heating
Hotels, offices, schools and public buildings.
Industrial Process Water
Indirect heating and temperature-control duties.
Laundry & Cleaning
Hot-water preparation after load review.
Food Facilities
Indirect hot-water duties with hygienic separation as required.
Remote Sites
Projects where fuel storage is undesirable and electricity is reliable.
Low-Noise Locations
Indoor plant rooms requiring quiet combustion-free operation.
FREQUENTLY ASKED QUESTIONS
CLDR Electric Hot Water Boiler FAQ.
Does CLDR produce local combustion emissions?
No fuel is burned in the boiler. Project environmental impact still depends on the electricity source and local rules.
Can 24–1,440 kW be selected directly from building area?
No. Select from a heat-loss or process heat-balance calculation, temperatures, operating profile and system losses.
Is 380 V suitable for every destination?
No. The listed range uses a 380 V / 50 Hz basis. The destination electrical standard and transformer capacity must be confirmed.
Does the boiler include circulation pumps?
The final pump quantity and duty are defined in the approved project scope.
Can CLDR connect to a closed circuit?
A closed or separated circuit can be engineered after pressure, expansion, safety and local-code requirements are confirmed.
What data is needed for a proposal?
Send heat load, temperatures, flow, system pressure, power supply, water quality, operating hours and destination.
TECHNICAL SELECTION
Send the Load, Utilities, Operating Conditions and Destination.
JINHONG will match the model, auxiliaries, controls and system boundary to the actual project data.